LYSAGHT® Zed & Cee Purlins and Girts

Product Description and Features

LYSAGHT® Purlins and Girts are lightweight structural steel members, designed in accordance with the AS/NZS 4600: 1996 Cold Formed Steel Structures utilising high strength zinc-coated steel.

Purlins and GirtsLYSAGHT® Zed sections may be used over single spans, unlapped and lapped continuous spans in multi-bay buildings. Lapped continuous spans result in considerable capacity increase in the system.

LYSAGHT® Cee sections may be used in single spans, and unlapped continuous spans in multi-bay building and are ideal as eave purlins or where compact sections are required for detailing.

Availability


NSW4 WA3 SA/NT QLD VIC/TAS
C 75 - - Yes (SA Only5) - -
C/Z 100 Yes Yes Yes Yes Yes
C/Z 150 - Yes Yes Yes Yes
C/Z 200 - Yes Yes Yes Yes
C/Z 250 - C 250 yes (Z2501) Yes2 Yes Yes
C/Z 300 - Yes Yes2 Yes1 Yes1
C/Z 350 - Yes Yes2 Yes1 Yes1

1 Extended lead times may apply. Contact your local service centre for availability
2 Price and availability subject to application. Extended lead times apply. Contact your nearest Lysaght service centre for availability.
3 A turn down lip is available on C/Z 150, C/Z 200, and C 250 purlins. Minimum order quantities are required.
4 For purlin availability in New South Wales, please see LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts
5 C 75 is only available in South Australia, and you can Download Section Properties for the South Australian Purlin; LYSAGHT Cee Purlin C7510 (216 KB)

Other purlin profiles may be available subject to application and will incur added charges &/or lead times.

Features

  • A range of gauges and depths are available
  • Can be provided punched and unpunched
  • Non-standard sizes may be available on application
  • A down-turned bottom lip on your LYSAGHT® Zed Purlin, is available on request.

Common Uses of this product

Cladding support system with other applications in portal frames and trusses

Warnings

  • LYSAGHT® Cee sections cannot be lapped
  • Cee and Zed purlins are normally supplied un-punched. If punching is required punching details should be specified at the time of ordering
  • Purlins should be stored off the ground and on a slight slope so that water can drain away
  • Direct contact of incompatible material with coating should be avoided. In such applications, suitable paint systems should be obtained from paint manufacturers
  • Consider orientation of Zed and Cee purlins in relation to possible build-up of substances such as dust or grain
  • Special transport requirements are needed for lengths over 12000mm
  • Span tables assume the use of LYSAGHT® bridging and LYSAGHT® recommended bolts

Product Details

Schematic

Cee Purlin Zed Purlin
Diagram 1 Diagram 2

Photo

Specification

LYSAGHT® Zed and Cee sections are roll-formed from GALVASPAN® steel complying with AS1397 - 1993. In the grades shown, the numbers prefixed with G indicate minimum yield stress in MPa. The numbers prefixed with Z indicate minimum coating mass in g/m2.

1.0mm BMT: G550, Z350*
1.2mm BMT: G500, Z350*
1.5, 1.9, 2.4 & 3.0 mm BMT: G450, Z350*

* All BMTs in Townsville have Z450 coating.

Dimensions

Catalogue number t mm D mm Mass per unit length kg/m Zeds Cees
E mm F mm L mm B mm L mm
Z/C10010
Z/C10012
Z/C10015
Z/C10019

Z/C15012
Z/C15015
Z/C15019
Z/C15024

Z/C20015
Z/C20019
Z/C20024

Z/C25019
Z/C25024

Z/C30024
Z/C30030

Z/C35030

1.0
1.2
1.5
1.9

1.2
1.5
1.9
2.4

1.5
1.9
2.4

1.9
2.4

2.4
3.0

3.0

102
102
102
102

152
152
152
152

203
203
203

254
254

300
300

350

1.78
2.10
2.62
3.29

2.89
3.59
4.51
5.70

4.49
5.74
7.24

6.50
8.16

10.09
12.76

15.23

53
53
53
53

65
65
65
66

79
79
79

79
79

100
100

129

49
49
49
49

61
61
61
60

74
74
73

74
73

93
93

121

12.5
12.5
13.5
14.5

15.5
16.5
17.5
19.5

15.0
18.5
21.5

18.0
21.0

27.0
31.0

30.0

51
51
51
51

64
64
64
64

76
76
76

76
76

96
96

125

12.5
12.5
13.5
14.5

14.5
15.5
16.5
18.5

15.5
19.0
21.0

18.5
20.5

27.5
31.5

30.0

NOTE: New South Wales designers must refer to the New South Wales LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts Range.

Holes and Cleats

Zed and Cee sections are normally supplied with holes punched to the Australian Institute of Steel Construction (AISC) gauge lines, except in Victoria where the 150 series sections are punched to the Structural Steel Fabricators Association, Victoria, recommended gauge lines.

Section Properties

Section properties for different purlin configurations can be found in the downloadable manual. Download LYSAGHT® Zed & Cee Purlins and Girts User Manual.

NOTE: New South Wales designers must refer to the New South Wales LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts Range.

Capacity & Load Tables

Limit State Capacity tables for different purlin configurations can be found in the user manual. Download LYSAGHT® Zed & Cee Purlins and Girts User Manual.

NOTE: New South Wales designers must refer to the New South Wales LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts Range.

Warranty

BlueScope Steel offers a warranty on application, of up to 10 years from the date of installation against perforation by natural degradation, when used within the building envelope.

Page location: http://www.roofingcentretas.com.au/cms/purlinsandgirts/awaitingcontent.php

This page was last updated Tuesday, 16 November 2010.
COLORBOND®, LYSAGHT®, TOPSPAN® & ZINCALUME® are trademarks of BlueScope Steel Limited.
The Roofing Centre is a wholly owned subsidiary of BlueScope Steel Limited. ABN 16 000 011 058.

Website design and development by Ionata Web Solutions, Tasmania