LYSAGHT® Zed & Cee Purlins and Girts
LYSAGHT® Purlins and Girts are lightweight structural steel members, designed in accordance with the AS/NZS 4600: 1996 Cold Formed Steel Structures utilising high strength zinc-coated steel.
LYSAGHT® Zed sections may be used over single spans, unlapped and lapped continuous spans in multi-bay buildings. Lapped continuous spans result in considerable capacity increase in the system.
LYSAGHT® Cee sections may be used in single spans, and unlapped continuous spans in multi-bay building and are ideal as eave purlins or where compact sections are required for detailing.
| | NSW4 | WA3 | SA/NT | QLD | VIC/TAS |
|---|---|---|---|---|---|
| C 75 | - | - | Yes (SA Only5) | - | - |
| C/Z 100 | Yes | Yes | Yes | Yes | Yes |
| C/Z 150 | - | Yes | Yes | Yes | Yes |
| C/Z 200 | - | Yes | Yes | Yes | Yes |
| C/Z 250 | - | C 250 yes (Z2501) | Yes2 | Yes | Yes |
| C/Z 300 | - | Yes | Yes2 | Yes1 | Yes1 |
| C/Z 350 | - | Yes | Yes2 | Yes1 | Yes1 |
1 Extended lead times may apply. Contact your local service centre for availability
2 Price and availability subject to application. Extended lead times apply. Contact your nearest Lysaght service centre for availability.
3 A turn down lip is available on C/Z 150, C/Z 200, and C 250 purlins. Minimum order quantities are required.
4 For purlin availability in New South Wales, please see LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts
5 C 75 is only available in South Australia, and you can Download Section Properties for the South Australian Purlin; LYSAGHT Cee Purlin C7510 (216 KB)
Other purlin profiles may be available subject to application and will incur added charges &/or lead times.
Cladding support system with other applications in portal frames and trusses
| Cee Purlin | Zed Purlin |
![]() | ![]() |
LYSAGHT® Zed and Cee sections are roll-formed from GALVASPAN® steel complying with AS1397 - 1993. In the grades shown, the numbers prefixed with G indicate minimum yield stress in MPa. The numbers prefixed with Z indicate minimum coating mass in g/m2.
1.0mm BMT: G550, Z350*
1.2mm BMT: G500, Z350*
1.5, 1.9, 2.4 & 3.0 mm BMT: G450, Z350*
* All BMTs in Townsville have Z450 coating.
| Catalogue number | t mm | D mm | Mass per unit length kg/m | Zeds | Cees | |||
|---|---|---|---|---|---|---|---|---|
| E mm | F mm | L mm | B mm | L mm | ||||
| Z/C10010 Z/C10012 Z/C10015 Z/C10019 Z/C15012 Z/C20015 Z/C25019 Z/C30024 Z/C35030 | 1.0 1.2 1.5 1.9 1.2 1.5 1.9 2.4 3.0 | 102 102 102 102 152 203 254 300 350 | 1.78 2.10 2.62 3.29 2.89 4.49 6.50 10.09 15.23 | 53 53 53 53 65 79 79 100 129 | 49 49 49 49 61 74 74 93 121 | 12.5 12.5 13.5 14.5 15.5 15.0 18.0 27.0 30.0 | 51 51 51 51 64 76 76 96 125 | 12.5 12.5 13.5 14.5 14.5 15.5 18.5 27.5 30.0 |
NOTE: New South Wales designers must refer to the New South Wales LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts Range.
Zed and Cee sections are normally supplied with holes punched to the Australian Institute of Steel Construction (AISC) gauge lines, except in Victoria where the 150 series sections are punched to the Structural Steel Fabricators Association, Victoria, recommended gauge lines.
Section properties for different purlin configurations can be found in the downloadable manual. Download LYSAGHT® Zed & Cee Purlins and Girts User Manual.
NOTE: New South Wales designers must refer to the New South Wales LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts Range.
Limit State Capacity tables for different purlin configurations can be found in the user manual. Download LYSAGHT® Zed & Cee Purlins and Girts User Manual.